Page 668 - The Central Motor Vehicles Rules, 1989
P. 668
640 THE CENTRAL MOTOR VEHICLE RULES, 1989 ANNEXURE IX
6.1 Gas Solenoid Valve* Testing of the component as per IS: IS: 15712 or ISO-15500
15712 or ISO-15500 by test agency.
Alternatively, test agency to verify the
test certificate or report conforming to
the above standard issued by
accredited testing laboratory.
Automatic valve of LNG System shall Automatic Valve for LNG
meet requirements of ECE R110 or System : ECE R110 or
equivalent standard equivalent standard
7. Filling Connection Installation on vehicle to be checked Clauses 2.2.2, 2.2.3, 2.2.4,
(NZS & NGV-1 type) by test agency as per AIS-028 2.2.5 and 2.2.6 of AIS-028
for CNG/LNG
receptacle
8. Ventilation Test agency to verify. Clause 2.4.2 of AIS-028
9. Testing of Conduit* Testing of the component or IS: 15715
verification of certificate or test report
as per IS: 15715 by test agency.
10. CNG/BIO-CNG/LNG fuel line
10.1 High pressure - 100 kPa*
exceeding
10.1.1 Exceeding 2.15 MPa - Testing of the component or IS: 15716
Rigid pipe verification of certificate or test report
as per IS: 15716 by test agency.
LNG rigid pipeline shall meet ECE R 110 or equivalent
requirements of ECE R110 or standard
equivalent standard
- Flexible hose Testing of the component or IS 15718
verification of certificate or test report
as per IS 15718 by test agency.
LNG pipeline shall meet ECE R110 or equivalent
requirements of ECE R110 or standard
equivalent standard
10.1.2 Pressure upto 2.15 Mpa Testing of the component or IS: 15722 with amendments
verification of certificate or test report
as per IS: 15722 by test agency.
LNG pipeline shall meet ECE R110 or equivalent
requirements of ECE R110 or standard
equivalent standard
10.2 Joints and connections* Testing by test agency. Clause 3.1.4.1, 3.2.1 (b) of
AIS-028
LNG joints & connection shall meet ECE R110 or equivalent
requirements of ECE R110 or standard
equivalent standard.